lijieelectrical@gmail.com
image
image

SZ18 type 35kV on-load tap-changing transformer

1. Voltage rating: 35KV; 2. Adjustable voltage (on-load tap changer); 3. Tap range: ±5%, ±2*2.5%; 4. Capacity range: 630-31500kVA; 5. Frequency: 50Hz, 60Hz; 6. Number of phases: Single-phase, three-phase; 7. Connection group designation: Yyno or Dyn11; 8. Impedance voltage: Conforms to the specifications in the technical parameter table (or as required by the user); 9. Operating environment: Maximum outdoor temperature not exceeding 40℃ (or as required by the user); 10. Cooling method: Oil immersion self-cooling.

Product Description

SZ18 Type 35kV On-Load Tap-Changing Transformer

When your facility demands uninterrupted voltage stability, the SZ18 type 35kV on-load tap-changing transformer delivers enterprise-grade performance you can trust. Manufactured by Lijie Electric Power Technology Group—a leading transformer specialist with over 2,000 employees and 160+ engineers across 500,000 square meters of advanced facilities—this transformer achieves GB 20052-2020 Level 1 energy efficiency standards. With capacity ranging from 630kVA to 31,500kVA and a ±5% tap adjustment range, it maintains precise voltage control without service interruption, making it ideal for industrial plants, renewable energy installations, and mission-critical infrastructure.

SZ18 type 35kV on-load tap-changing transformer

Why Choose Our On-Load Tap-Changing Solution?

Uninterrupted Voltage Stability

Your operations can't manage downtime. Our on-load tap-changer alters voltage in real-time whereas your framework remains energized. No control interferences. No generation delays. Fair smooth, persistent operation indeed when network conditions fluctuate.

Maximum Vitality Efficiency

Every kilowatt things to your foot line. This transformer meets Level 1 vitality proficiency prerequisites, conveying the most reduced operational misfortunes in its lesson. For offices running 24/7, the vitality reserve funds rapidly include up—reducing your power costs year after year.

Built for Requesting Environments

Whether you're overseeing a semiconductor fab, a wind cultivate, or a clinic, this item handles challenging conditions. Planned for open air temperatures up to 40°C with oil-immersed self-cooling, it keeps up unwavering quality in cruel climates and heavy-load scenarios.

Flexible Arrangement Options

Your application is one of a kind. That's why we offer broad customization: 50Hz or 60Hz recurrence, single-phase or three-phase arrangements, Yyn0 or Dyn11 association bunches, and impedance voltage custom-made to your determinations. Generation cycles run from 6 to 30 days based on your necessities.

Technical Specifications

Parameter Specification
Voltage Rating 35kV
Capacity Range 630 - 31,500 kVA
Tap Adjustment Range ±5%, ±2×2.5%
Regulation Type On-load tap-changing
Frequency 50Hz / 60Hz
Phases Single-phase or Three-phase
Connection Group Yyn0 or Dyn11
Cooling Method Oil-immersed self-cooling (ONAN)
Energy Efficiency GB 20052-2020 Level 1
Operating Temperature Max 40°C outdoor (customizable)
Standards Compliance ISO 9001:2015, IEC, CE certified

SZ18 type 35kV on-load tap-changing transformer

Who Benefits Most from This Transformer?

Heavy Industrial Facilities

Steel plants, chemical plants, and semiconductor production lines work around the clock. Hardware harm from voltage changes can taken a toll millions. Our transformer gives the exact, real-time voltage direction your generation lines require whereas minimizing vitality waste.

Renewable Vitality Projects

Wind and sun powered establishments confront steady yield varieties. If you're overseeing a 100MW+ renewable vitality base, this transformer stabilizes framework association voltage, guarantees compliance with utility necessities, and maximizes your plant's productivity through decreased misfortunes.

Mission-Critical Infrastructure

Hospitals, data centers, and transit systems cannot tolerate power quality issues. Operating rooms, server farms, and subway control systems require rock-solid voltage stability. This SZ18 type 35kV on-load tap-changing transformer protects your critical equipment from voltage-related failures.

Quality You Can Verify

All our transformers experience thorough testing at China's National Transformer Quality Supervision and Assessment Center and Wuhan Tall Voltage Investigate Established. We hold ISO 9001:2015, CE, IEC, and UL certifications—validating our commitment to universal quality standards.

Our fabricating offices in Xuzhou and Nantong utilize progressed generation hardware with visualized following frameworks. This guarantees reliable quality control and on-time conveyance for your projects.

SZ18 type 35kV on-load tap-changing transformer

Frequently Asked Questions

Q: Can the transformer alter voltage without closing down my facility?

Yes, that's the essential advantage of on-load tap-changing innovation. Voltage alterations happen whereas your framework remains completely operational, dispensing with expensive generation interruptions.

Q: What's the commonplace lead time for a customized unit?

Production cycles run from 6 to 30 days depending on your determinations and capacity prerequisites. Contact our specialized group with your extend points of interest for an precise timeline.

Q: How does Level 1 vitality proficiency decipher to take a toll savings?

Level 1 appraised transformers minimize no-load and stack misfortunes. For an office working ceaselessly, this can decrease yearly power costs by thousands of dollars compared to standard proficiency units—the reserve funds compound over the transformer's 25+ year lifespan.

Q: Is this transformer reasonable for cruel climate conditions?

Standard units work dependably in open air temperatures up to 40°C. We can customize cooling frameworks and defensive highlights for extraordinary situations. Share your particular climate conditions, and we'll prescribe the ideal configuration.

Q: What documentation and bolster do you provide?

You'll get total specialized drawings, operation manuals, test reports, and establishment direction. Our group gives progressing specialized bolster and save parts supply all through your transformer's benefit life.

Get Expert Guidance for Your Project

Our engineering team is here to help you select the right SZ18 type 35kV on-load tap-changing transformer configuration. Email us at lijieelectrical@gmail.com today.

Customer reviews background image

Here are some reviews from our users:

April 27, 2025

With a tight project schedule, the manufacturer delivered on time, and on-site technical personnel provided guidance throughout the entire installation and commissioning process; the collaboration was highly efficient and hassle-free.

July 2, 2025

During the preliminary phase, a selection plan was custom-tailored based on the actual site load requirements, resulting in a high degree of parameter compatibility. After-sales support responds within two hours, and ongoing technical support for operation and maintenance is comprehensive; we feel completely confident in a long-term partnership.

November 18, 2025

Deployed as a supporting component for a 35kV grid-connection project at a photovoltaic power station, the equipment operates for an average of 16 hours daily. It demonstrates excellent control over no-load losses, ensures smooth power generation and grid integration, and effectively reduces the station's overall energy consumption.

January 30, 2026

Under the continuous, high-load operating conditions of a factory production line, the equipment maintains stable electrical parameters and exhibits strong overload resistance, thereby guaranteeing an uninterrupted power supply for industrial production.

April 3, 2026

Integrated as a supporting component for a new energy photovoltaic grid-connection system, the manufacturer provided professional technical coordination and timely after-sales support, ensuring seamless adaptation to the specific electrical operating conditions required for grid integration.

Online Message Leave your information so that we can contact you.