April 27, 2025
With a tight project schedule, the manufacturer delivered on time, and on-site technical personnel provided guidance throughout the entire installation and commissioning process; the collaboration was highly efficient and hassle-free.
Our Amorphous iron core rod type distribution transformer from Lijie Electric combines advanced amorphous alloy technology with flexible pole-mounted design. With capacity ranging from 15-167kVA and efficiency improvements up to 70% in no-load losses compared to conventional silicon steel cores, this transformer delivers exceptional performance for distributed power supply. Our production spans two 500,000㎡ manufacturing bases with over 160 engineers ensuring quality. Installation takes just hours, costs 40-60% less than traditional substations, and adapts perfectly to your changing power needs.

The undefined combination center decreases vitality squander essentially. You'll take note lower power bills from day one. The material's one of a kind nuclear structure minimizes attractive misfortunes amid operation.
No require for costly foundation. Your transformer mounts specifically on existing utility posts. This spares important ground space and kills building costs entirely.
Time things in your ventures. Our framework introduces and works inside hours. You get prompt control supply when you require it most.
| Parameter | Specification |
|---|---|
| Voltage Level | 8kV, 20kV |
| Voltage Regulation | Non-excitation tap changing |
| Tap Range | +1/-3×2.5%, +0/-4×2.5% |
| Capacity Range | 15-167kVA |
| Frequency | 50Hz / 60Hz |
| Phase Configuration | Single-phase, Three-phase |
| Impedance Voltage | As per standard specifications |
| Operating Temperature | Up to 40℃ outdoor environment |
| Cooling Method | Oil-immersed self-cooling |
| Insulation Level | Power frequency: AC-35kV / Impulse: 75kV |
| Production Cycle | 6-30 days (customizable) |

You avoid civil engineering entirely. No foundations, no buildings, no lengthy construction. Your total investment drops 40-60% compared to box-type substations. Budget-conscious projects benefit immediately.
Limited space? No problem. The pole-mounted configuration works perfectly in crowded urban areas and dispersed rural locations. Your existing infrastructure supports the unit.
The Amorphous iron core rod type distribution transformer operates with minimal losses. Lower no-load current means reduced operating costs year after year. Your energy bills reflect real savings.
Inspections become straightforward. All components remain visible and accessible. Your maintenance team works faster with less downtime. Testing procedures simplify considerably.
Load patterns change over time. This transformer relocates easily when your needs shift. You adapt to new requirements without major reinvestment.
Install close to consumption points. Short low-voltage lines reduce transmission losses. Your end-users enjoy better voltage quality and reliability.
Rustic Jolt: Culminate for scattered farmhouses and agrarian offices where conventional substations demonstrate uneconomical.
Temporary Control Supply: Development destinations, occasions, and crisis circumstances advantage from quick arrangement capabilities.
Railway Frameworks: Trackside establishments for signaling and assistant control requirements.
Suburban Improvement: Developing private regions with advancing control demands.
Remote Areas: Precipitous districts and zones with challenging territory where framework venture must remain minimal.

Our fabricating takes after ISO 9001:2015 guidelines. Items carry CE, UL, and IEC certifications. Each item experiences thorough testing at the National Transformer Quality Supervision and Review Center.
With yearly deals surpassing 5 billion RMB and establishments over Australia, Modern Zealand, India, Vietnam, Malaysia, Indonesia, Kazakhstan, Egypt, and Kenya, Lijie Electric serves clients worldwide.
You get total specialized documentation counting drawings, operation manuals, and test reports. Our group gives establishment direction and progressing specialized bolster all through your transformer's benefit life.
Q: How long does installation take?
A: Typically just a few hours. The pole-mounted design allows for quick assembly and immediate operation once electrical connections are completed.
Q: Can I relocate this transformer later?
A: Yes, absolutely. Disassembly and relocation are straightforward. This makes the unit ideal for changing load conditions or line modifications.
Q: What maintenance does it require?
A: Regular visual inspections and periodic oil testing. The accessible design simplifies all maintenance procedures compared to enclosed substation types.
Q: Is customization available?
A: Yes. We tailor specifications to your requirements. Production cycles range from 6-30 days depending on customization complexity.
Q: How does amorphous core compare to silicon steel?
A: Amorphous alloy reduces no-load losses by approximately 70%. This translates to significant energy savings over the transformer's lifetime.
Q: What voltage regulation options exist?
A: Non-excitation tap changing with ranges of +1/-3×2.5% or +0/-4×2.5%. This maintains output voltage within acceptable limits despite grid fluctuations.
Contact our technical team today at lijieelectrical@gmail.com to discuss your specific requirements for Amorphous iron core rod type distribution transformer and receive a customized solution.
YOU MAY LIKE
April 27, 2025
With a tight project schedule, the manufacturer delivered on time, and on-site technical personnel provided guidance throughout the entire installation and commissioning process; the collaboration was highly efficient and hassle-free.
July 2, 2025
During the preliminary phase, a selection plan was custom-tailored based on the actual site load requirements, resulting in a high degree of parameter compatibility. After-sales support responds within two hours, and ongoing technical support for operation and maintenance is comprehensive; we feel completely confident in a long-term partnership.
November 18, 2025
Deployed as a supporting component for a 35kV grid-connection project at a photovoltaic power station, the equipment operates for an average of 16 hours daily. It demonstrates excellent control over no-load losses, ensures smooth power generation and grid integration, and effectively reduces the station's overall energy consumption.
January 30, 2026
Under the continuous, high-load operating conditions of a factory production line, the equipment maintains stable electrical parameters and exhibits strong overload resistance, thereby guaranteeing an uninterrupted power supply for industrial production.
April 3, 2026
Integrated as a supporting component for a new energy photovoltaic grid-connection system, the manufacturer provided professional technical coordination and timely after-sales support, ensuring seamless adaptation to the specific electrical operating conditions required for grid integration.